Closed-loop detector thermal-control screening for survival hold and operational set-point maintenance.
e7299394ee064c9cc1ae90143c5a37f3f3657daab38c5a3e8f4110b6756999297.000 / 7.000 WThe detector control sensor and heater channels are evaluated against
the released detector thermal node, which currently traces
to the detector cold-finger hardware.
detector_control on thermal node detector
as primary_control: detector cold-finger interface
immediately behind the focal detector package.detector_mount_guard on thermal node
detector_mount as guard: detector mount clamp
saddle adjacent to the cold-finger clamp split line.focal_plane_monitor on thermal node
focal_plane as monitor: focal-plane package
rear electronics deck near the readout boxes.detector_heater_primary on thermal node
detector as primary_survival:
4.500 W max at primary foil heater bonded to the detector
cold-finger root.detector_heater_redundant on thermal node
detector as redundant_survival:
2.500 W max at redundant foil heater bonded to the opposite
detector cold-finger face.thermal_control_sensor_roles_complete: PASSthermal_control_heater_capacity_matches_budget:
PASSsurvival_hold_passes: PASSoperational_setpoint_passes: PASStransient1 from hot1 at
30.0 s steps for 28800.0 sdetector: 91.008 ->
90.999 K; min/max 90.995 /
91.008 K0.008 K; settle time:
0.0 s0.002 K, max
0.004 K0.089 W, energy
0.336 Wh109.926 K119.398 Ktransient1 from cold1 at
30.0 s steps for 28800.0 sdetector: 82.559 ->
92.022 K; min/max 82.559 /
92.067 K0.067 K; settle time:
1620.0 s0.024 K, max
0.029 K7.000 W, energy
35.483 Wh100.297 K104.456 K