This is a screening-level thermoelastic optical-stability gate built from the released optical STOP thermal cases. Line-of-sight stability is reported as a line-of-sight-equivalent image-motion proxy inferred from chief-ray registration shift at the released plate scale.
PASSe7299394ee064c9cc1ae90143c5a37f3f3657daab38c5a3e8f4110b6756999290.400000 arcsec400.000 um45.000 nm RMSHothot_contaminated_85_0_1.500.011664 arcsec56.348 um8.139 nm RMS-4.563 um18.297 um-3.092 K11.049 KColdcold_nominal0.005178 arcsec8.681 um1.254 nm RMS0.631 um13.943 um0.000 K8.420 Koptical_stop_design_signature_present: PASSthermal_cases_present: PASSworst_hot_case_line_of_sight_within_requirement:
PASSworst_hot_case_focus_shift_within_requirement:
PASSworst_hot_case_wfe_within_requirement: PASSworst_cold_case_line_of_sight_within_requirement:
PASSworst_cold_case_focus_shift_within_requirement:
PASSworst_cold_case_wfe_within_requirement: PASSstability_envelope.png should show hot and cold LOS
bars comfortably below the 0.4 arcsec line and focus bars in the
tens-to-low-hundreds of micron range, not millimetres or zeros from a
broken conversion.thermal_distortion_breakdown.png should show the hot
case carrying the larger secondary/focal thermal deltas and the larger
thermoelastic distortion terms, without any sign flip that contradicts
the reported case temperatures.